TITLE 32: ENERGY
CHAPTER II: ILLINOIS EMERGENCY MANAGEMENT AGENCY SUBCHAPTER b: RADIATION PROTECTION PART 422 LICENSING OF RADON DETECTION AND MITIGATION SERVICES SECTION 422.70 CONDITIONS OF LICENSES
Section 422.70 Conditions of Licenses
a) Any person licensed by the Agency to perform radon measurement shall perform in accordance with the measurement protocol provided in Section 422.130 of this Part as applicable to the measurement type performed and the device(s) used.
b) Any person licensed by the Agency to perform radon measurements shall use devices approved by USEPA or the Agency to measure radon and radon progeny.
c) No unlicensed individual shall perform radon measurement or mitigation activities without the direct on-site supervision of a licensed individual.
d) Within 45 days after providing radon measurements, the individual providing the service shall report the results in picocuries per liter (pCi/L) to the occupant, the owner of the building, his/her representatives or the client.
e) Licensees shall comply with 32 Ill. Adm. Code 340. This means that the radiation exposure shall not exceed 30 pCi/L or 0.3 WL, based on continuous workplace exposure for 40 hr/week, 52 weeks per year and shall not exceed 4 working level months (WLM) over a 12 month period, using an equilibrium ratio of 50 percent to convert radon exposure to WLM.
f) Records of radon measurements, mitigations, Quality Assurance Programs, calibration measurements, equipment repairs and worker protection plans shall be retained by the licensee for a least 5 years or the length of time of any warranty or guarantees, whichever is longer.
g) No person shall interfere with, or cause another to interfere with, the successful completion of a radon measurement or the installation or operation of a radon mitigation.
h) The radon laboratory licensee shall notify the Agency in writing within 5 working days when it loses or replaces the individual named pursuant to Section 422.60(e)(1) of this Part.
i) Mitigators who are also licensed to perform measurements shall not perform radon measurements before or after the installation of a mitigation system at the same address as the mitigation installation, unless a measurement has been made by another independent person in accordance with this Part.
j) Licensees shall inform the Agency of changes in biographical information, such as addresses and telephone numbers, within 10 days after the change is effective.
k) Substantive changes to license application representations require an amendment to the license and Agency approval. Licensees shall request amendments to documents at least 30 days prior to the effective date of the desired revision.
l) The licensee shall comply with the Agency-approved Quality Assurance Program.
m) Professional licensees shall be located in Illinois or within 50 miles of the Illinois border. Professional licensees shall provide general supervision of technician licensees working under their Quality Assurance Program.
n) Contractors installing research or innovative radon techniques or otherwise deviating from the standards in this Part shall notify the Agency in writing 7 working days prior to the commencement of work. When such research is conducted, a performance standard shall be applied, for example, post-mitigation radon levels shall be below USEPA's action level (4.0 pCi/L). Written notification to the Agency shall include:
1) Written acknowledgement signed by the client stating that the client understands the reasons the contractor plans to deviate from the standards of this Part;
2) The technical bases for the measurement or mitigation technique and a description of the functional accomplishments that will be achieved; and
3) The identity of the client and the address of the building, including the zip code.
(Source: Amended at 29 Ill. Reg. 3212, effective February 22, 2005) |