The first step is to perform a short-term measurement* in the lowest structural areas**.

 

*      Short-term tests may last between 2 and 90 days, most last between 2 and 7 days.  Examples of short-term detectors used in home environment testing include: activated charcoal canisters, liquid scintillation vials, electret chambers and continuous monitors.  Examples of long-term detectors used in home environment testing include:  alpha track detectors and electret chambers.

 

**    Conduct a short-term test in each of the lowest structural areas suitable for occupancy in the home.  For example, if the home is a split-level building with one or more foundation types: test in the basement, in a room over the crawlspace and in a slab-on-grade room.  In accordance with this protocol, measurement licensees are required to test in each of the foundation types.

 