Section 14.APPENDIX H Heliport/Vertiport Standards,
Facility Requirements and Restrictions on Use
Section 14.TABLE A Heliport Standards
|
Standard
|
Heliport/ Helistop
Vertiport/ Vertistop
Public-Use
|
Heliport/ Helistop
Vertiport/ Vertistop
Private-Use
|
Heliport/ Helistop
Vertiport/ Vertistop
Restricted Landing Area
|
Heliport/ Helistop
Vertiport/ Vertistop
Hospital
|
|
Minimum TLOF (Helipad) Size*
|
1 Rotor Diameter
|
1 Rotor Diameter
|
1 Rotor Diameter (Recommended)
|
1 Rotor Diameter (40’ Minimum)
|
|
Minimum FATO (Clear Area) Size
|
2 x Rotor Diameter (100’ Minimum)
|
2 x Rotor Diameter (100’ Minimum)
|
2 x Rotor Diameter (100’ Minimum)
|
2 x Rotor Diameter (100’ Minimum)
|
|
Approach/ Departure Path Requirements
|
2 – 90º Apart Minimum (with 2:1 side transition)
8:1 Min. Slope
|
2 – 90º Apart Minimum (with 2:1 side transition)
8:1 Min. Slope
|
2 – 90º Apart Minimum
1st Approach -8:1 Min. Slope
2nd Approach -may be 5:1 Min. Slope if
necessary
|
2 – 90º Apart Minimum
1st Approach -8:1 Min. Slope
2nd Approach - may be 5:1 Min. Slope if necessary
|
*NOTE: A 6” REINFORCED CONCRETE TLOF IS RECOMMENDED. If a
concrete TLOF is not used, the FATO edges and center must be marked.
Section 14.APPENDIX H Heliport/Vertiport Standards,
Facility Requirements and Restrictions on Use
Section 14.TABLE B Facility Requirements
|
Item
|
Heliport/ Helistop
Vertiport/ Vertistop
Public-Use
|
Heliport/ Helistop
Vertiport/ Vertistop
Private-Use
|
Heliport/ Helistop
Vertiport/ Vertistop
Restricted Landing Area
|
Hospital Heliport/ Helistop
Vertiport/ Vertistop
|
|
24-Hour Phone
|
Required for heliport only.
|
Not Required
|
Not Required
|
Not Required
|
|
Access Control
a) Spectator
b) Vehicular
c) Perimeter
|
Required
Required
Required
|
Recommended
Recommended
Recommended
|
Recommended
Recommended
Recommended
|
Required
Required
Required
Security and access may be controlled by hospital.
|
|
Fire Protection
|
Required for heliports – one 20# extinguisher (two where
fueling is present).
|
Required for heliports – one 20# extinguisher (two where
fueling is present).
|
Recommended
|
Required – one 20# extinguisher (two where fueling is
present).
|
|
First-Aid Kit
|
Required for heliport only.
|
Recommended for heliport.
|
Not Required
|
Not Required
|
|
Fuel & Oil Sales
|
Required for heliport during normal business hours.
Available by phone after business hours.
|
Not Required
|
Not Required
|
Not Required
|
|
Hangar/Office
|
Required for heliport only.
|
Not Required
|
Not Required
|
Not Required
|
|
Identification Beacons
|
Required for heliports.
|
Recommended
|
Not Required
|
Recommended and required for all Trauma Centers.
|
Item
|
Heliport/ Helistop
Vertiport/ Vertistop
Public-Use
|
Heliport/ Helistop
Vertiport/ Vertistop
Private-Use
|
Heliport/ Helistop
Vertiport/ Vertistop
Restricted Landing Area
|
Hospital Heliport/ Helistop Vertiport/ Vertistop
|
|
Lead-in Lights and Arrows
|
Required for heliports.
|
Recommended
|
Not Required
|
Recommended
|
|
Marked FATO and/or TLOF Identifiable from 500' AGL
|
Required
|
Required
|
Required
|
Required
|
|
Paved TLOF
|
Recommended
|
Recommended
|
Not Required
|
Recommended
|
|
Perimeter/Flood Lighting
|
Required for night use.
|
Required for night use.
|
Recommended for night use.
|
Required for night use.
|
|
Potable Water
|
Required for heliport during normal business hours.
Available by phone after business hours.
|
Not Required
|
Not Required
|
Not Required
|
|
Horizontal Safety Fence for Heliports Elevated 30” or
Higher
|
Required
|
Required
|
Required
|
Required
|
|
Sanitary Restroom
|
Required for heliport during normal business hours.
Available by phone after business hours.
|
Not Required
|
Not Required
|
Not Required
|
|
Wind Direction / Velocity Indicator (must be lighted for
night use)
|
Required
|
Required
|
Required
|
Required
|
Section 14.APPENDIX H Heliport/Vertiport Standards,
Facility Requirements and Restrictions on Use
Section 14.TABLE C Restrictions on Use
|
Use
|
Heliport/ Helistop
Vertiport / Vertistop
Public-Use
|
Heliport/ Helistop
Vertiport / Vertistop
Private-Use
|
Heliport/ Helistop
Vertiport / Vertistop
Restricted Landing Area
|
Hospital Heliport/ Helistop
Vertiport / Vertistop
|
|
Based Aircraft
|
No Restrictions
|
No Restrictions
|
Maximum of Six Based Helicopters.
|
Maximum of Six Based Helicopters.
|
|
Carrying of Passengers for Hire
|
Allowed
|
Allowed
|
Prohibited as Based Operation
|
EMS only
|
|
Commercial Maintenance
|
Allowed for heliports only
|
Allowed for heliports only
|
Prohibited
|
Prohibited
|
|
Flight Instruction
|
Unrestricted
|
Unrestricted
|
a) Restricted to immediate family of Certificate Holder
(excluding cert. held by corp.). Non-continuous.
b) Specialized dual instruction originating from a
bonafide flight training operation based at a heliport.
|
Prohibited
|
|
Through-the-Fence Operations
|
Allowed
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
|
Agricultural Operations
|
Allowed
|
Allowed
|
Allowed
|
Not Applicable
|
|
Application of De-icing Agents
|
Only non-corrosive de-icing agents allowed.
|
Only non-corrosive de-icing agents allowed.
|
Only non-corrosive de-icing agents allowed.
|