TITLE 32: ENERGY
CHAPTER II: ILLINOIS EMERGENCY MANAGEMENT AGENCY SUBCHAPTER b: RADIATION PROTECTION PART 310 GENERAL PROVISIONS FOR RADIATION PROTECTION SECTION 310.140 UNITS OF EXPOSURE AND RADIATION DOSE
Section 310.140 Units of Exposure and Radiation Dose
a) As used in 32 Ill. Adm. Code: Chapter II, Subchapters b and d, the unit of exposure is the coulomb per kilogram (C/kg) or roentgen (R). One roentgen (R) is equal to 2.58 x 10-4 C/kg.
b) As used in 32 Ill. Adm. Code: Chapter II, Subchapters b and d, the units of radiation dose are:
1) "Gray" (Gy) is the SI unit of absorbed dose. One Gy is equal to an absorbed dose of 1 joule per kilogram (J/kg). (1 Gy = 100 rad).
2) "Rad" is the special unit of absorbed dose. One rad is equal to an absorbed dose of 100 ergs per gram or 0.01 joule per kilogram (J/kg). (1 rad = 0.01 Gy).
3) "Rem" is the special unit of any of the quantities expressed as dose equivalent. The dose equivalent in rem is equal to the absorbed dose in rad multiplied by the quality factor (1 rem = 0.01 Sv).
4) "Sievert" (Sv) is the SI unit of any of the quantities expressed as dose equivalent. The dose equivalent in sievert is equal to the absorbed dose in gray multiplied by the quality factor (1 Sv = 100 rem).
c) As used in 32 Ill. Adm. Code: Chapter II, Subchapters b and d, the quality factors for converting absorbed dose to dose equivalent are as follows:
d) If it is more convenient to measure the neutron fluence rate than to determine the neutron dose equivalent rate in rem per hour or sievert per hour, as provided in subsection (c) of this Section, 0.01 Sv (1 rem) of neutron radiation of unknown energies may, for purposes of 32 Ill. Adm. Code: Chapter II, Subchapters b and d, be assumed to result from a total fluence of 25 million neutrons per square centimeter incident upon the body. If sufficient information exists to estimate the approximate energy distribution of the neutrons, the licensee may convert a measured tissue dose in gray (rad) to dose equivalent in sievert (rem) by using the fluence rate per unit dose equivalent or the appropriate Q value shown below.
(Source: Amended at 23 Ill. Reg. 14454, effective January 1, 2000) |