TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER c: EMISSION STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES
PART 216 CARBON MONOXIDE EMISSIONS
SECTION 216.361 PETROLEUM AND PETROCHEMICAL PROCESSES


 

Section 216.361  Petroleum and Petrochemical Processes

 

a)         No person shall cause or allow the emission of a carbon monoxide waste gas stream into the atmosphere from a petroleum or petrochemical process unless such waste gas stream is burned in a direct flame afterburner or carbon monoxide boiler so that the resulting concentration of carbon monoxide in such waste gas stream is less than or equal to 200 ppm corrected to 50 percent excess air, or such waste gas stream is controlled by other equivalent air pollution control equipment approved by the Agency according to the provisions of 35 Ill. Adm. Code 201.

 

b)         Notwithstanding subsection (a), any existing petroleum or petrochemical process using catalyst regenerators of fluidized catalytic converters equipped for in situ combustion of carbon monoxide, may emit a carbon monoxide waste gas stream into the atmosphere if the carbon monoxide concentration of such waste gas stream is less than or equal to 750 ppm corrected to 50 percent excess air.

 

c)         Notwithstanding subsection (a), any new petroleum or petrochemical process using catalyst regenerators of fluidized catalytic converters equipped for in situ combustion of carbon monoxide, may emit a carbon monoxide waste gas stream into the atmosphere if the carbon monoxide concentration of such waste gas stream is less than or equal to 350 ppm corrected to 50 percent excess air.