TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE C: WATER POLLUTION
CHAPTER I: POLLUTION CONTROL BOARD
PART 302 WATER QUALITY STANDARDS
SECTION 302.535 AMMONIA NITROGEN


 

Section 302.535  Ammonia Nitrogen

 

The Open Waters of Lake Michigan as defined in Section 302.501 must not exceed 0.02 mg/L total ammonia (as N).  The remaining waters of the Lake Michigan Basin are subject to the following:

 

a)         Total ammonia nitrogen (as N) must in no case exceed 15 mg/L.

 

b)         Un-ionized ammonia nitrogen (as N) must not exceed the acute and chronic standards given below subject to the provisions of Section 302.208(a) and (b):

 

1)         From April through October, the Acute Standard (AS) must be 0.33 mg/L and the chronic standard (CS) must be 0.057 mg/L.

 

2)         From November through March, the AS must be 0.14 mg/L and the CS must be 0.025 mg/L.

 

c)         For this Section, the concentration of un-ionized ammonia nitrogen as N and total ammonia as N must be computed according to the following equations:

 

U

=

N

[0.94412(1 + 10x) + 0.0559]

 

and N = U[0.94412(1 + 10x) + 0.0559]

 

Where:

 

X

=

0.09018

+

2729.92

-pH

(T + 273.16)

U

=

Concentration of un-ionized ammonia as N in mg/L

N

=

Concentration of ammonia nitrogen as N in mg/L

T

=

Temperature in degrees Celsius.

 

(Source:  Amended at 47 Ill. Reg. 4437, effective March 23, 2023)