SLUDGE
APPLICATION METHOD
|
Incorporation or Injection...........................
|
20 ft. from occupied dwelling. 10 ft. from closet edge of
traveled portion of public road or within fence. 200 ft. from surface water.
|
|
|
Ridge and Furrow.......................................
|
200 ft. from occupied dwelling. 200 ft. from closest edge
of traveled portion of public road or within fence. 200 ft. from surface
water.
|
|
|
Dewatered material or Splash Plate to Land Surface...............................................
|
200 ft. from occupied dwelling. 200 ft. from closest edge
of traveled portion of primary and secondary public roads; or 10 ft. from
closest edge public roads; or within fence. 200 ft. from surface water.
|
|
|
Low Pressure Sprayers (<50
psi (as measured from outer boundary of spray)....................................................
|
200 ft. from occupied dwelling. 200 ft. from closest edge
of traveled portion of public road. 200 ft. from surface water, waterways or
flood plains. Wind velocity <15 mph.
|
|
|
High Pressure Sprayers
(>50 psi) (as measured from outer boundary of spray)..................................................
|
1000 ft. from occupied dwelling. 1000 ft. from closest
edge of traveled portion of public road. 1000 ft. from surface water,
waterways or flood plains. Wind velocity <15 mph.
|
GEOLOGICAL
CONSIDERATIONS
|
Minimum Depth of Earth Cover to the Mean Annual Water Tale............................
|
10 ft. with rapid permeability (greater than 2.0
inches/hr)
5 ft. with moderate to slow permeability (less than 2.0
inches/hour)
|
|
|
Distance from Potable Water Well.............
|
150 ft. in all instances, however, if a water supply is
located in a consolidated bedrock (such as limestone) or sinkhole area and is
within one-fourth of a mile of the sludge application site, then 50 foot
depth of non-sandy, non-gravelly unconsolidated material is needed for water
supply protection
|
TOPOGRAPHIC
CONSIDERATIONS
|
Maximum Slope..........................................
|
8% (incorporation)*
|
|
5% (surface application)*
|
|
|
Application to Waterways...........................
|
Not allowed
|
|
|
Application in a flood plain having
a flooding frequency more often than once every ten years...........................
|
Only if approved by Agency after review of project.
|
|
|
*May be exceeded under certain conditions. See discussion
in Section 391.404.
|