Section 728.APPENDIX F Technologies
to Achieve Deactivation of Characteristics
The treatment standard for many
characteristic wastes is stated in Table T, entitled "Treatment Standards
for Hazardous Wastes", as "DEACT and meet Section 728.148
standards". USEPA has determined that many technologies, when used alone
or in combination, can achieve the deactivation portion of the treatment
standard. Characteristic wastes that are not managed in a facility regulated
by the CWA or in a CWA-equivalent facility, and that also contain underlying
hazardous constituents (see Section 728.102(i)) must be treated not only by a
"deactivating" technology to remove the characteristic, but also to
achieve the universal treatment standards (UTS) for underlying hazardous
constituents. This Appendix F presents a partial list of technologies,
utilizing the five letter technology codes established in Table C, that may be
useful in meeting the treatment standard. Use of these specific technologies
is not mandatory and does not preclude direct reuse, recovery or the use of
other pretreatment technologies, provided deactivation is achieved and
underlying hazardous constituents are treated to achieve the UTS.
|
USEPA hazardous waste
number/subcategory
|
Nonwastewaters
|
Wastewaters
|
|
D001 Ignitable Liquids
based on 35 Ill. Adm. Code 721.121(a)(1) – Low TOC Nonwastewater Subcategory
(containing one percent to <10 percent TOC)
|
RORGS
WETOX
INCIN
CHOXD
BIODG
|
n.a.
|
|
D001 Ignitable Liquids
based on 35 Ill. Adm. Code 721.121(a)(1) – Ignitable Wastewater Subcategory
(containing <one percent TOC)
|
n.a.
|
WETOX
RORGS
INCIN
CHOXD
BIODG
|
|
D001 Compressed Gases
based on 35 Ill. Adm. Code 721.121(a)(3)
|
RCGAS
FSUBS
INCIN
ADGAS fb.
INCIN
ADGAS fb.
(CHOXD; or
CHRED)
|
n.a.
|
|
D001 Ignitable
Reactives based on 35 Ill. Adm. Code 721.121(a)(2)
|
WTRRX
CHOXD
CHRED
STABL
INCIN
|
n.a.
|
|
D001 Ignitable
Oxidizers based on 35 Ill. Adm. Code 721.121(a)(4)
|
CHRED
INCIN
|
CHRED
INCIN
|
|
D002 Acid Subcategory
based on 35 Ill. Adm. Code 721.122(a)(1) with pH less than or equal to two
|
RCORR
NEUTR
INCIN
|
NEUTR
INCIN
|
|
D002 Alkaline
Subcategory based on 35 Ill. Adm. Code 721.122(a)(1) with pH greater than or
equal to 12.5
|
NEUTR
INCIN
|
NEUTR
INCIN
|
|
D002 Other Corrosives
based on 35 Ill. Adm. Code 721.122(a)(2)
|
CHOXD
CHRED
INCIN
STABL
|
CHOXD
CHRED
INCIN
|
|
D003 Water Reactives
based on 35 Ill. Adm. Code 721.123(a)(2), (a)(3), and (a)(4)
|
INCIN
WTRRX
CHOXD
CHRED
|
n.a.
|
|
D003 Reactive Sulfides
based on 35 Ill. Adm. Code 721.123(a)(5)
|
CHOXD
CHRED
INCIN
STABL
|
CHOXD
CHRED
BIODG
INCIN
|
|
D003 Explosives based on
35 Ill. Adm. Code 721.123(a)(6), (a)(7), and (a)(8)
|
INCIN
CHOXD
CHRED
|
INCIN
CHOXD
CHRED
BIODG
CARBN
|
|
D003 Other Reactives based
on 35 Ill. Adm. Code 721.123(a)(1)
|
INCIN
CHOXD
CHRED
|
INCIN
CHOXD
CHRED
BIODG
CARBN
|
|
K044 Wastewater
treatment sludges from the manufacturing and processing of explosives
|
CHOXD
CHRED
INCIN
|
CHOXD
CHRED
BIODG
CARBN
INCIN
|
|
K045 Spent carbon from
the treatment of wastewaters containing explosives
|
CHOXD
CHRED
INCIN
|
CHOXD
CHRED
BIODG
CARBN
INCIN
|
|
K047 Pink/red water
from TNT operations
|
CHOXD
CHRED
INCIN
|
CHOXD
CHRED
BIODG
CARBN
INCIN
|
Note: "n.a."
stands for "not applicable".
"fb." stands
for "followed by".
(Source: Amended at 42 Ill.
Reg. 24924, effective November 19, 2018)