TITLE 77: PUBLIC HEALTH
CHAPTER I: DEPARTMENT OF PUBLIC HEALTH
SUBCHAPTER q: MOBILE HOMES
PART 870 MANUFACTURED HOME INSTALLATION CODE
SECTION 870.TABLE E PIER LOAD AND MINIMUM PIER CAPACITY FOR 12 FOOT WIDE SECTION (POUNDS)



Section 870.TABLE E   Pier Load and Minimum Pier Capacity for 12 Foot Wide Section (Pounds)

 

 

Roof Live Load (psf)

Mating/Perimeter Wall Opening (feet)

5

10

15

20

25

30

35

 

20

900

1800

2600

3500

4400

5300

6100

 

30

1200

2300

3500

4700

5800

7000

8200

 

40

1500

2900

4400

5800

7300

8800*

10200*

Soil's Load- Bearing Capacity (psf)

Footing Area (square inches)

1000

20

144

259

374

504

634

763

878

30

173

331

504

677

835

1008

1181

40

216

417

634

835

1051

1267

1469

1500

20

144

173

250

336

422

509

586

30

144

221

336

451

557

672

787

40

144

278

422

557

701

845

979

2000

20

144

144

187

252

317

382

439

30

144

166

252

338

418

504

590

40

144

209

317

418

526

634

734

3000

20

144

144

144

168

211

254

293

30

144

144

168

226

278

336

394

40

144

144

211

278

350

422

490

4000

20

144

144

144

144

191

191

220

30

144

144

144

169

209

252

295

40

144

144

158

209

263

317

367

 

*    Individual supports shall NOT support loads greater than 8000 pounds for a single stack of 8"x8"x16" stack of blocks, 14000 pounds for a double stack.