TITLE 77: PUBLIC HEALTH
CHAPTER I: DEPARTMENT OF PUBLIC HEALTH
SUBCHAPTER q: MOBILE HOMES
PART 870 MANUFACTURED HOME INSTALLATION CODE
SECTION 870.TABLE F PIER LOAD AND MINIMUM PIER CAPACITY FOR 14 FOOT WIDE SECTION (POUNDS)



Section 870.TABLE F   Pier Load and Minimum Pier Capacity for 14 Foot Wide Section (Pounds)

 

 

Roof Live Load (psf)

Mating/Perimeter Wall Opening (feet)

5

10

15

20

25

30

35

 

20

1000

2000

3000

4100

5100

6100

7100

 

30

1400

2700

4100

5400

6800

8100*

9500*

 

40

1700

3400

5100

6800

8400*

10100*

11800*

Soil's Load- Bearing Capacity (psf)

Footing Area (square inches)

1000

20

144

288

432

590

734

878

1022

30

202

389

590

778

979

1166

1368

40

245

490

734

979

1210

1454

1699

1500

20

144

192

288

394

490

586

682

30

144

259

394

518

653

778

912

40

163

326

490

653

806

970

1133

2000

20

144

144

216

295

367

439

511

30

144

194

295

389

490

583

684

40

144

245

367

490

605

727

850

3000

20

144

144

144

197

245

293

341

30

144

144

197

260

326

389

456

40

144

163

245

326

403

485

566

4000

20

144

144

144

148

184

220

256

30

144

144

148

194

245

292

342

40

144

144

184

245

302

364

425

 

*    Individual supports shall NOT support loads greater than 8000 pounds for a single stack of 8"x8"x16" stack of blocks, 14000 pounds for a double stack.