TITLE 77: PUBLIC HEALTH
CHAPTER I: DEPARTMENT OF PUBLIC HEALTH SUBCHAPTER r: WATER AND SEWAGE
PART 890
ILLINOIS PLUMBING CODE
SECTION 890.APPENDIX A PLUMBING MATERIALS, EQUIPMENT, USE RESTRICTIONS AND APPLICABLE STANDARDS
Section 890.APPENDIX A Plumbing
Materials, Equipment, Use Restrictions and Applicable Standards
Section 890.TABLE K Size
and Length of Vents
Size
of Soil or Waste Stack
|
Fixture
Units Connected
|
Diameter
of Vent Required (Inches)
|
1¼
|
1½
|
2
|
2½
|
3
|
4
|
5
|
6
|
8
|
Maximum
Length of Vent (Feet)
|
1¼
|
2
|
30
|
|
|
|
|
|
|
|
|
1½
|
8
|
50
|
150
|
|
|
|
|
|
|
|
1½
|
10
|
30
|
100
|
|
|
|
|
|
|
|
2
|
12
|
30
|
75
|
200
|
|
|
|
|
|
|
2
|
20
|
26
|
50
|
150
|
|
|
|
|
|
|
2½
|
42
|
|
30
|
100
|
300
|
|
|
|
|
|
3
|
10
|
|
30
|
100
|
200
|
600
|
|
|
|
|
3
|
30
|
|
|
60
|
200
|
500
|
|
|
|
|
3
|
60
|
|
|
50
|
60
|
400
|
|
|
|
|
4
|
100
|
|
|
35
|
100
|
260
|
1,000
|
|
|
|
4
|
200
|
|
|
30
|
90
|
250
|
900
|
|
|
|
4
|
500
|
|
|
20
|
70
|
180
|
700
|
|
|
|
5
|
200
|
|
|
|
35
|
80
|
350
|
1,000
|
|
|
5
|
500
|
|
|
|
30
|
70
|
300
|
900
|
|
|
5
|
1,100
|
|
|
|
20
|
50
|
200
|
700
|
|
|
6
|
350
|
|
|
|
25
|
50
|
200
|
400
|
1,300
|
|
6
|
620
|
|
|
|
15
|
30
|
125
|
300
|
1,100
|
|
6
|
960
|
|
|
|
|
24
|
100
|
250
|
1,000
|
|
6
|
1,900
|
|
|
|
|
20
|
70
|
200
|
700
|
|
8
|
600
|
|
|
|
|
|
50
|
150
|
500
|
1,300
|
8
|
1,400
|
|
|
|
|
|
40
|
100
|
400
|
1,200
|
8
|
2,200
|
|
|
|
|
|
30
|
80
|
350
|
1,100
|
9
|
3,600
|
|
|
|
|
|
25
|
60
|
250
|
800
|
10
|
1,000
|
|
|
|
|
|
|
75
|
125
|
1,000
|
10
|
2,500
|
|
|
|
|
|
|
50
|
100
|
500
|
10
|
3,800
|
|
|
|
|
|
|
30
|
80
|
350
|
10
|
5,600
|
|
|
|
|
|
|
25
|
60
|
250
|
Agency Note: Per Section
890.1580(e), no more than 20 percent of the maximum developed length may be
installed in the horizontal position. Vent piping serving floor drains shall be
installed in such a manner as to minimize horizontal vent distances.
|