TITLE 77: PUBLIC HEALTH
CHAPTER I: DEPARTMENT OF PUBLIC HEALTH
SUBCHAPTER r: WATER AND SEWAGE
PART 905 PRIVATE SEWAGE DISPOSAL CODE
SECTION 905.APPENDIX A ILLUSTRATIONS AND EXHIBITS


 

Section 905.APPENDIX A   Illustrations and Exhibits

 

Section 905.ILLUSTRATION C   List of Approved Plastic Pipe for Private Sewage

Disposal System

 

 

 

 

 

 

TYPES OF PIPES

ASTM

STANDARD

BUILDING

SEWER 1

OR COMMON

COLLECTOR

SEWER

LINES 1

ALL

SUBSURFACE

SEEPAGE

SYSTEMS

 

 

5 ft. from building to septic-aeration tank to 5 ft. beyond the septic tank, aeration tank or distribution box

 

Additional treatment facilities and sand filter distribution lines and collection lines

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS

(DWV Schedule 40)

F628-06

x

x

x

ABS

(DWV Schedule 40)

D2661-06

x

x

x

ABS

 

D1527-99

(2005)

x

x

x

ABS

(Sewer Pipe)

D2751-05

x2

x2

x2

PVC

 

D1785-06

x

x

x

PVC

(DWV Schedule 40)

D2665-07

x

x

x

PVC

(DWV Schedule 40)

F891-04

x

x

x

PVC

(Type PSM) (SDR 35)

D3034-06

x2

x2

x2

 

 

 

 

 

 

PVC

(Sewer & Drain

PS-50)

F891-04

x

x

x

PVC

(Sewer & Drain

PS-25)

F891-04

x

x

 

PVC

(Corrugated-Smoothwall)

F949-06

x

x

 

PVC

(Std. or Perforated)

D2729-03

 

x

x

PE

(Smoothwall)

R810-07

 

x

x

 

 

AASHTO

Standard

M252-06

 

 

 

PE

(Corrugated-Perforated)

F405-05

(Heavy Duty Only)

 

 

x

PE

(Corrugated-(Perforated)

F667-06

 

 

x

 

 

x –

Indicates approved use.

l       Plastic materials shall not be co-mingled within this area except through the use of proper adapters. (See Illinois Plumbing Code.) When the building sewer is of a type of material that is different from the building drain, proper transition fittings shall be used.

2      Pipe shall be SDR (Standard Dimension Ratio) 35 only.

Note:

The last 2 numbers of the ASTM Standard indicate the date of the edition.

 

(Source:  Amended at 37 Ill. Reg. 14994, effective August 28, 2013)