MINIMUM DISTANCE
ALLOWABLE FROM 1,2
|
|
|
Artificial Drain
|
|
COMPONENT PART OF SYSTEM
|
Cistern Well, or Suction Line from Pump To Well
|
Water Supply Line3 Pressure
|
Lake, Stream In ground Swimming Pool or Other Body of
Water
|
Property Dwelling
|
Property Line4
|
|
FEET
|
FEET
|
FEET
|
FEET
|
FEET
|
FEET
|
|
Building Sewer 5
|
50
|
10
|
25
|
–
|
–
|
–
|
|
Septic Tank or
Aerobic Treatment Plant
|
50
|
109
|
25
|
5
|
5
|
–
|
|
Distribution Box
|
75
|
10
|
25
|
10
|
5
|
–
|
|
Subsurface
Seepage System
|
75
|
25
|
25
|
10
|
5
|
10
|
|
Sand Filter
|
75
|
25
|
15
|
10
|
5
|
10
|
|
Privy
|
75
|
25
|
25
|
20
|
5
|
10
|
|
Waste
Stabilization Pond
|
75
|
25
|
25
|
20
|
5
|
10
|
|
Surface
Discharge Effluent Line
|
50
|
10
|
–
|
–
|
5
|
–
|
|
Effluent Receiving
Trench
|
75
|
25
|
15
|
10
|
5
|
10
|
|
Treated
Effluent Discharge Point6
|
50
|
10
|
−
|
20
|
25
|
25
|
|
Class V
Injection Wells7
|
2008
|
25
|
25
|
10
|
5
|
10
|
|
1 These
distances have been determined for use in clay, silt and loam soils only.
The minimum distances required for use in sand or other types of soil shall
be determined for the proposed private sewage disposal system and approved
by the Department. Approval will be given if the Department determines that
the soil will provide treatment of the sewage.
|
2 For
separation distances to closed loop wells, see 77 Ill. Adm. Code 920.180.
|
3 See Section 905.20(d) for additional details on water
line and sewer separation.
|
4 If a common property is used, the boundary of the
common property shall be used.
|
5 The building sewer or surface discharge effluent line
may be located to within 10 feet of a well or suction line from the pump to
the well when cast iron pipe with mechanical joints or Schedule 40 PVC pipe
with watertight joints is used for the building sewer or surface discharge
effluent line.
|
6 Any surface discharging system installed, repaired or
renovated after January 1, 2014.
|
7 Class V Injection Wells are defined in Illinois
Pollution Control Board rules. They are typically a shallow well used to
place fluids directly below the land surface. See, e.g., 35 Ill. Adm. Code
704.105. 704.106 and 704.280.
|
8 A lesser separation distance may be obtained with
approval or a waiver from IEPA.
|
9There shall be 25 feet separation from public water
supply water mains and water service lines. The terms public water supply,
water main and water service line shall have the same meaning as in the
Illinois Pollution Control Board's Public Water Supplies rules. See, e.g.,
35 Ill. Adm. Code 653.118 and 653.119.
|
|
|