TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER c: EMISSIONS STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES
PART 215 ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS
SECTION 215.432 INSPECTION PROGRAM FOR LEAKS


 

Section 215.432  Inspection Program for Leaks

 

The owner or operator of a synthetic organic chemical or polymer manufacturing plant subject to Section 215.430 through 215.439, shall for the purpose of detecting leaks, conduct a component inspection program utilizing the test methods specified in USEPA Reference Method 21, 40 CFR 60, Appendix A (1986), incorporated by reference in Section 215.105, consistent with the following provisions:  

 

a)         Test annually those components operated near extreme temperature or pressure such that they would be unsafe to routinely monitor, and those components located more than two meters above permanent worker access structures or surfaces;

 

b)         Test quarterly all other pressure relief valves in gas service, pumps in light liquid service, valves in light liquid service and in gas service, and compressors.

 

c)         If less than or equal to 2 percent of the valves in light liquid service and in gas service tested pursuant to subsection (b) are found not to leak for 5 consecutive quarters, no leak tests shall be required for three consecutive quarters.  Thereafter, leak tests shall resume for the next quarter.  If that test shows less than or equal to 2 percent of the valves in light liquid service and in gas service are leaking, then no tests are required for the next 3 quarters.  If more than 2 percent are leaking, then tests are required for the next 5 quarters.

 

d)         Observe visually all pump seals weekly.

 

e)         Test immediately any pump seal in light liquid service from which liquids are observed dripping.

 

f)         Test any relief valve within 24 hours after it has vented to the atmosphere.

 

g)         Routine instrument monitoring of valves which are not externally regulated, flanges, and components in heavy liquid service, is not required. However, any valve which is not externally regulated, flange, or component in heavy liquid service that is found to be leaking on the basis of sight, smell or sound shall be repaired as soon as practicable but no later than 30 days after the leak is found.

 

h)         Test immediately after repair any component that was found leaking.

 

i)          Within 1 hour of its detection, a weatherproof, readily visible tag, in bright colors such as red or yellow, bearing an identification number and the date on which the leak was detected must be affixed on the leaking component and remain in place until the leaking component is repaired.

 

j)          Any component that is in vacuum service or any pressure relief devices connected to an operating flare header or to a vapor recovery devices is exempt from the monitoring requirements in this Section.

 

(Source:  Amended at 13 Ill. Reg. 10893, effective June 27, 1989)