TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION CHAPTER I: POLLUTION CONTROL BOARD SUBCHAPTER c: EMISSIONS STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES PART 219 ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE METRO EAST AREA SECTION 219.407 EMISSION LIMITATIONS AND CONTROL REQUIREMENTS FOR LITHOGRAPHIC PRINTING LINES
Section 219.407 Emission Limitations and Control Requirements for Lithographic Printing Lines
a) No owner or operator of lithographic printing lines subject to the requirements of this Subpart shall:
1) Cause or allow the operation of any heatset web offset lithographic printing line unless:
A) The total VOM content in the as-applied fountain solution meets one of the following conditions:
i) 1.6 percent or less, by weight;
ii) 3 percent or less, by weight, and the temperature of the fountain solution is maintained below 15.6°C (60°F), measured at the reservoir or the fountain tray; or
iii) 5 percent or less, by weight, and the as-applied fountain solution contains no alcohol;
B) The air pressure in the dryer is maintained lower than the air pressure of the press room, such that air flow through all openings in the dryer, other than the exhaust, is into the dryer at all times when the printing line is operating;
C) An afterburner is installed and operated so that VOM emissions (excluding methane and ethane) from the press dryer exhausts are reduced as follows:
i) Prior to August 1, 2010, by 90 percent, by weight, or to a maximum afterburner exhaust outlet concentration of 20 ppmv (as carbon); and
ii) On and after August 1, 2010, by at least 90 percent, by weight, for afterburners first constructed at the source prior to January 1, 2010; by at least 95 percent, by weight, for afterburners first constructed at the source on or after January 1, 2010; or to a maximum afterburner exhaust outlet concentration of 20 ppmv (as carbon);
D) The afterburner complies with all monitoring provisions specified in Section 219.410(c) of this Subpart; and
E) The afterburner is operated at all times when the printing line is in operation, except the afterburner may be shut down between November 1 and April 1 as provided in Section 219.107 of this Part;
2) Cause or allow the operation of any non-heatset web offset lithographic printing line unless the VOM content of the as-applied fountain solution is 5 percent or less, by weight, and the as-applied fountain solution contains no alcohol;
3) Cause or allow the operation of any sheet-fed offset lithographic printing line unless:
A) The VOM content of the as-applied fountain solution is 5 percent or less, by weight; or
B) The VOM content of the as-applied fountain solution is 8.5 percent or less, by weight, and the temperature of the fountain solution is maintained below 15.6°C (60°F), measured at the reservoir or the fountain tray;
4) Cause or allow the use of a cleaning solution on any lithographic printing line unless:
A) The VOM content of the as-used cleaning solution is less than or equal to:
i) 30 percent, by weight; or
ii) On and after August 1, 2010, for owners or operators of sources that meet the applicability criteria in Section 219.405(c)(3) and do not certify pursuant to Section 219.411(g)(1)(B) that the source will not make use of any of the exclusions in Section 219.405(c)(3), 70 percent, by weight; or
B) The VOM composite partial vapor pressure of the as-used cleaning solution is less than 10 mmHg at 20°C (68°F);
5) Cause or allow VOM containing cleaning materials, including used cleaning towels, associated with any lithographic printing line to be kept, stored or disposed of in any manner other than in closed containers, except when specifically in use.
b) An owner or operator of a heatset web offset lithographic printing line subject to the requirements of Section 219.407(a)(1)(C) of this Subpart may use a control device other than an afterburner, if:
1) The control device reduces VOM emissions from the press dryer exhausts as follows:
A) Prior to August 1, 2010, by at least 90 percent, by weight, or to a maximum control device exhaust outlet concentration of 20 ppmv (as carbon); and
B) On and after August 1, 2010:
i) By at least 90 percent, by weight, for control devices first constructed at the source prior to January 1, 2010;
ii) By at least 95 percent, by weight, for control devices first constructed at the source on or after January 1, 2010; or
iii) To a maximum control device exhaust outlet concentration of 20 ppmv (as carbon);
2) The owner or operator submits a plan to the Agency detailing appropriate monitoring devices, test methods, recordkeeping requirements, and operating parameters for the control device; and
3) The use of the control device with testing, monitoring, and recordkeeping in accordance with this plan is approved by the Agency and USEPA as federally enforceable permit conditions.
(Source: Amended at 34 Ill. Reg. 9253, effective June 25, 2010) |