A single topographic map of the proposed project and the area within 2,500 ft. of the project shall be submitted as a part of the engineering design. Segmented maps may be provided for large projects.  The topographic map shall show the following information:

 

a)         Application area boundaries including buffer zones;

 

b)         Treatment and storage facilities;

 

c)         Piping and layout of the irrigation system;

 

d)         Present and proposed land use regarding residences, buildings, developments, public access areas, etc;

 

e)         Present and proposed water supply wells and abandoned wells and shafts;

 

f)         Direction of groundwater movement and any points of groundwater resurfacing;

 

g)         Surface waters and waterways, wetlands and 10-year floodplains;

 

h)         Subsurface drainage tiles and storm sewers; and

 

i)          Slopes of the application areas.