09400HB1614ham001 |
- 2 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| purchase of local goods and services.
|
| 2 |
| Section 10. Definitions. As used in this Act:
|
| 3 |
| "Department" means the Department of Commerce and Economic |
| 4 |
| Opportunity. |
| 5 |
| "Ballast" means a device used with an electric discharge |
| 6 |
| lamp to obtain necessary circuit conditions (voltage, current |
| 7 |
| and waveform) for starting and operating the lamp. |
| 8 |
| "Boiler" means a self-contained appliance for supplying |
| 9 |
| steam or hot water primarily intended for space-heating and |
| 10 |
| which utilizes only single-phase electric current, or |
| 11 |
| single-phase electric current or DC current in conjunction with |
| 12 |
| natural gas, propane, or home heating oil, and which: |
| 13 |
| (1) is designed to be the principal heating source for |
| 14 |
| the living space of one or more residences; |
| 15 |
| (2) has a heat input rate of less than 300,000 Btu per |
| 16 |
| hour; and |
| 17 |
| (3) is not an appliance designed for the primary |
| 18 |
| purpose of supplying hot water for purposes other than |
| 19 |
| heating. |
| 20 |
|
"Compensation" means money or any other valuable thing, |
| 21 |
| regardless of form, received or to be received by a person for |
| 22 |
| services rendered. |
| 23 |
| "Electricity ratio" means the ratio of furnace electricity |
| 24 |
| use to total furnace energy use. Electricity ratio = |
| 25 |
| (3.412*EAE)/(1000*EF + 3.412*EAE) where EAE and EF are defined in |
| 26 |
| Title 10 of the Code of Federal Regulations. |
| 27 |
| "Furnace" means a self-contained space heater designed to |
| 28 |
| supply heated air through ducts of more than 10 inches length |
| 29 |
| and which utilizes only single-phase electric current, or |
| 30 |
| single-phase electric current or DC current in conjunction with |
| 31 |
| natural gas, propane, or home heating oil, and which: |
| 32 |
| (1) is designed to be the principle heating source for |
| 33 |
| the living space of one or more residences; |
|
|
|
09400HB1614ham001 |
- 3 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| (2) is not contained within the same cabinet with a |
| 2 |
| central air conditioner whose rated cooling capacity is |
| 3 |
| above 65,000 Btu per hour; and |
| 4 |
| (3) has a heat input rate of less than 225,000 Btu per |
| 5 |
| hour. |
| 6 |
| "High-intensity discharge lamp" means a lamp in which light |
| 7 |
| is produced by the passage of an electric current through a |
| 8 |
| vapor or gas and in which the light-producing arc is stabilized |
| 9 |
| by bulb wall temperature and the arc tube has a bulb wall |
| 10 |
| loading in excess of 3 watts per square centimeter. |
| 11 |
| "Medium voltage dry-type distribution transformer" means a |
| 12 |
| transformer that: |
| 13 |
| (1) has an input voltage of more than 600 volts but |
| 14 |
| less than or equal to 34,500 volts; |
| 15 |
| (2) is air-cooled; |
| 16 |
| (3) does not use oil as a coolant; and |
| 17 |
| (4) is rated for operation at a frequency of 60 Hertz. |
| 18 |
| "Metal halide lamp" means a high-intensity discharge lamp |
| 19 |
| in which the major portion of the light is produced by |
| 20 |
| radiation of metal halides and their products of dissociation, |
| 21 |
| possibly in combination with metallic vapors. |
| 22 |
| "Metal halide lamp fixture" means a light fixture designed |
| 23 |
| to be operated with a metal halide lamp and a ballast for a |
| 24 |
| metal halide lamp. |
| 25 |
| "Probe-start metal halide ballast" means a ballast used to |
| 26 |
| operate metal halide lamps which does not contain an igniter |
| 27 |
| and which instead starts lamps by using a third starting |
| 28 |
| electrode probe in the arc tube. |
| 29 |
| "Single-voltage external AC to DC power supply" means a |
| 30 |
| device that: |
| 31 |
| (1) is designed to convert line voltage AC input into |
| 32 |
| lower voltage DC output; |
| 33 |
| (2) is able to convert to only one DC output voltage at |
| 34 |
| a time; |
|
|
|
09400HB1614ham001 |
- 4 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| (3) is sold with, or intended to be used with, a |
| 2 |
| separate end-use product that constitutes the primary |
| 3 |
| power load; |
| 4 |
| (4) is contained within a separate physical enclosure |
| 5 |
| from the end-use product; |
| 6 |
| (5) is connected to the end-use product via a removable |
| 7 |
| or hard-wired male/female electrical connection, cable, |
| 8 |
| cord or other wiring; |
| 9 |
| (6) does not have batteries or battery packs, including |
| 10 |
| those that are removable, that physically attach directly |
| 11 |
| to the power supply unit; |
| 12 |
| (7) does not have a battery chemistry or type selector |
| 13 |
| switch and indicator light, or does not have a battery |
| 14 |
| chemistry or type selector switch and a state of charge |
| 15 |
| meter; and |
| 16 |
| (8) has a nameplate output power less than or equal to |
| 17 |
| 250 watts. |
| 18 |
| "State-regulated incandescent reflector lamp" means a |
| 19 |
| lamp, not colored or designed for rough or vibration service |
| 20 |
| applications, with an inner reflective coating on the outer |
| 21 |
| bulb to direct the light, an E26 medium screw base, a rated |
| 22 |
| voltage or voltage range that lies at least partially within |
| 23 |
| 115 to 130 volts and that falls into either of the following |
| 24 |
| categories: a bulged reflector, elliptical reflector, blown |
| 25 |
| parabolic aluminized reflector or similar bulb shape with a |
| 26 |
| diameter equal to or greater than 2.25 inches; or a reflector, |
| 27 |
| parabolic aluminized reflector, bulged reflector or similar |
| 28 |
| bulb shape with a diameter of 2.25 to 2.75 inches, inclusive. |
| 29 |
| "Transformer" means a device consisting of 2 or more coils |
| 30 |
| of insulated wire and that is designed to transfer alternating |
| 31 |
| current by electromagnetic induction from one coil to another |
| 32 |
| to change the original voltage or current value. This term does |
| 33 |
| not include: (1) devices with multiple voltage taps, with the |
| 34 |
| highest voltage tap equaling at least 20% more than the lowest |
|
|
|
09400HB1614ham001 |
- 5 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| voltage tap; or (2) devices, such as those commonly known as |
| 2 |
| drive transformers, rectifier transformers, auto-transformers, |
| 3 |
| uninterruptible power system transformers, impedance |
| 4 |
| transformers, regulating transformers, sealed and |
| 5 |
| non-ventilating transformers, machine tool transformers, |
| 6 |
| welding transformers, grounding transformers, or testing |
| 7 |
| transformers, that are designed to be used in a special-purpose |
| 8 |
| application and are unlikely to be used in general-purpose |
| 9 |
| applications.
|
| 10 |
| Section 15. Scope.
|
| 11 |
| (a) The provisions of this Act apply to the testing, |
| 12 |
| certification, and enforcement of efficiency standards for the |
| 13 |
| following types of new products sold, offered for sale, or |
| 14 |
| installed in this State: |
| 15 |
| (1) medium voltage dry-type distribution transformers; |
| 16 |
| (2) metal halide lamp fixtures; |
| 17 |
| (3) furnaces and boilers; |
| 18 |
| (4) single-voltage external AC to DC power supplies; |
| 19 |
| and |
| 20 |
| (5) State-regulated incandescent reflector lamps. |
| 21 |
| (b) The provisions of this Act do not apply to: |
| 22 |
|
(1) new products
manufactured in this State and sold |
| 23 |
| outside this State; |
| 24 |
| (2) new products
manufactured outside this State and |
| 25 |
| sold at wholesale inside this State for
final retail sale |
| 26 |
| and installation outside this State; |
| 27 |
| (3) products installed
in mobile manufactured homes at |
| 28 |
| the time of construction; |
| 29 |
| (4) products
designed expressly for installation and |
| 30 |
| use in recreational vehicles; or
|
| 31 |
| (5) Stock available for sale at retail on the effective |
| 32 |
| date of this Act.
|
|
|
|
09400HB1614ham001 |
- 6 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| Section 20. Efficiency standards. The initial minimum |
| 2 |
| efficiency standards
for the types of new products set forth in |
| 3 |
| Section 15 are as follows:
|
| 4 |
| (1) Medium voltage dry-type distribution transformers |
| 5 |
| shall meet minimum efficiency levels three-tenths of a |
| 6 |
| percentage point higher than the Class 1 efficiency levels |
| 7 |
| for medium voltage distribution transformers specified in |
| 8 |
| Table 4-2 of the "Guide for Determining Energy Efficiency |
| 9 |
| for Distribution Transformers" published by the National |
| 10 |
| Electrical Manufacturers Association (NEMA Standard |
| 11 |
| TP-1-2002). |
| 12 |
| (2) Metal halide lamp fixtures designed to be operated |
| 13 |
| with lamps rated greater than or equal to 150 watts but |
| 14 |
| less than or equal to 500 watts shall not contain a |
| 15 |
| probe-start metal halide ballast. |
| 16 |
| (3) Furnaces and boilers shall meet or exceed the |
| 17 |
| applicable Annual Fuel Utilization Efficiency (AFUE) |
| 18 |
| levels in the following table: |
|
| 19 | | Product Type | Minimum Efficiency Level |
|
| 20 | | Gas and propane furnaces | 90% AFUE |
|
| 21 | | Oil furnaces | 83% AFUE |
|
| 22 | | Gas and propane hot water | |
|
| 23 | | boilers | 84% AFUE |
|
| 24 | | Gas and propane steam | |
|
| 25 | | boilers | 82% AFUE |
|
| 26 | | Oil-fired steam | |
|
| 27 | | boilers | 82% AFUE |
|
| 28 |
| Residential furnace air handlers shall have an ER of 2% |
| 29 |
| or less, except that residential oil furnaces with a |
| 30 |
| capacity of less than 94,000 Btu per hour shall have an ER |
| 31 |
| of 2.3% or less. |
| 32 |
| (4) Single-voltage external AC to DC power supplies |
| 33 |
| shall meet the tier 1 energy efficiency requirements of |
| 34 |
| California Code of Regulations, Title 20, Section 1605.3 as |
|
|
|
09400HB1614ham001 |
- 7 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| published in April 2005. This standard applies to |
| 2 |
| single-voltage AC to DC power supplies that are sold |
| 3 |
| individually and to those that are sold as a component of |
| 4 |
| or in conjunction with another product. |
| 5 |
| (5) State-regulated incandescent reflector lamps shall |
| 6 |
| meet the minimum average lamp efficiency requirements for |
| 7 |
| federally-regulated incandescent reflector lamps contained |
| 8 |
| in 42 U.S.C. section 6295 (i)(1)(A). The following lamps |
| 9 |
| are exempt from these requirements: ER30, BR30, BR40, and |
| 10 |
| ER40 of 50 watts or less; BR30, BR40, and ER40 of 65 watts; |
| 11 |
| and R20 of 45 watts or less.
|
| 12 |
| Section 25. Implementation.
|
| 13 |
| (a) On and after January 1, 2008, no new medium voltage |
| 14 |
| dry-type distribution transformer, single-voltage external AC |
| 15 |
| to DC power supply, or State-regulated incandescent reflector |
| 16 |
| lamp may be sold or offered for sale in the State unless the |
| 17 |
| efficiency of the new product meets or exceeds the efficiency |
| 18 |
| standards set forth in Section 20. |
| 19 |
| On and after January 1, 2009, no new metal halide lamp |
| 20 |
| fixture may be sold or offered for sale in the State unless the |
| 21 |
| efficiency of the product meets or exceeds the efficiency |
| 22 |
| standards set forth in Section 20. |
| 23 |
| In consultation with the Attorney General, the Department |
| 24 |
| shall determine if implementation of State standards for |
| 25 |
| furnaces and boilers requires a waiver from federal preemption, |
| 26 |
| and, if necessary, shall apply for such waiver within 18 months |
| 27 |
| of the effective date of this Act. If the Department determines |
| 28 |
| that a waiver from federal preemption is necessary for State |
| 29 |
| furnace and boiler standards, the State standards shall go into |
| 30 |
| effect at the earliest date permitted by federal law. If the |
| 31 |
| Department determines that a waiver from federal preemption is |
| 32 |
| not needed for State furnace and boiler standards, then the |
| 33 |
| State standards shall go into effect on June 1, 2008. |
|
|
|
09400HB1614ham001 |
- 8 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| (b) One year after the date upon which sale or offering for |
| 2 |
| sale of certain products is limited pursuant to subsection (a), |
| 3 |
| no new products may be installed for compensation in the State |
| 4 |
| unless the efficiency of the new product meets or exceeds the |
| 5 |
| efficiency standards set forth in Section 20.
|
| 6 |
| Section 35. Testing, certification, labeling, and |
| 7 |
| enforcement.
|
| 8 |
| (a) The manufacturers of new products subject to this Act |
| 9 |
| shall cause
samples of such products to be tested in accordance |
| 10 |
| with the appropriate test
procedures. With respect to |
| 11 |
| efficiency standards adopted by reference under
Section 20, the |
| 12 |
| appropriate test methods shall be those specified in the
|
| 13 |
| adopted standards.
|
| 14 |
| (b) Manufacturers of new products subject to this Act shall |
| 15 |
| certify to the
Department that such products are in compliance |
| 16 |
| with the provisions of this Act.
The Department may adopt |
| 17 |
| procedures and requirements governing the certification
of |
| 18 |
| such products and may work in coordination with the |
| 19 |
| certification programs
of other states. With respect to a |
| 20 |
| product for which the Illinois efficiency
standards and |
| 21 |
| labeling requirements are the same as those of the federal
|
| 22 |
| government or another state, the Department may accept as |
| 23 |
| sufficient for compliance
with this subsection the |
| 24 |
| manufacturer's certification to the federal government
or that |
| 25 |
| other state, whichever is applicable, that the product complies |
| 26 |
| with
those standards and requirements.
|
| 27 |
| (c) Manufacturers of new products subject to this Act shall |
| 28 |
| identify each
such product offered for sale or installation in |
| 29 |
| this State as in compliance
with the provisions of this Act by |
| 30 |
| means of a mark, label, or tag on the
product and packaging at |
| 31 |
| the time of sale or installation. The Department shall
propose |
| 32 |
| and shall adopt rules governing the identification of such
|
| 33 |
| products and packaging and may work in coordination with the |
|
|
|
09400HB1614ham001 |
- 9 - |
LRB094 02880 RSP 55144 a |
|
|
| 1 |
| labeling programs
of other states.
|
| 2 |
| (d) The Department may cause investigations to be made of |
| 3 |
| complaints
received concerning violations of this Act and may |
| 4 |
| report the results
of such investigations to the Attorney |
| 5 |
| General. The Attorney General may
institute proceedings to |
| 6 |
| enforce the provisions of this Act.
|
| 7 |
| (e) A manufacturer, distributor, retailer, or installer |
| 8 |
| who violates any
provision of this Act shall be issued a |
| 9 |
| warning by the Department for the first
violation. Repeat |
| 10 |
| violations shall be subject to a civil penalty of not more
than |
| 11 |
| $250. Each violation shall constitute a separate offense, and |
| 12 |
| each day
that a violation continues shall constitute a separate |
| 13 |
| offense. Penalties
assessed under this subsection are in |
| 14 |
| addition to costs assessed under
subsection (d).
|
| 15 |
| (f) The Department may propose and adopt any rules that are
|
| 16 |
| necessary to ensure the proper implementation and enforcement |
| 17 |
| of this Act.
|
| 18 |
| (g) Subject to appropriation, the Department may create and |
| 19 |
| maintain any programs, including, but not limited to, technical |
| 20 |
| assistance, education, and public awareness programs, that the |
| 21 |
| Department deems necessary for the implementation of this Act.
|
| 22 |
| Section 97. Severability. The provisions of this Act are |
| 23 |
| severable under
Section 1.31 of the Statute on Statutes.
|
| 24 |
| Section 99. Effective date. This Act takes effect upon |
| 25 |
| becoming law.".
|