(225 ILCS 705/15.08) (from Ch. 96 1/2, par. 1508)
Sec. 15.08.
When a compressed air tube fails to discharge, the air line leading to the tube shall be disconnected at the blow-down valve and the
tube shall be dragged by means of the air line to a safe place. The tube
shall be marketed with warning signs and repair work shall not be done on a
tube or shell until the pressure is reduced to zero. Except, however, this
provision shall not apply to shells or tubes charged from a shooting valve
that can be reversed and the air let out to reduce the pressure in the
shell or tube to zero.
(Source: Laws 1953, p. 701.)
|